OmniSwitch 6250 Chassis and Hardware Components Overtemp Condition
OmniSwitch 6250 Hardware Users Guide September 2015 page 3-33
10/100/1000 Mbps Power over Ethernet Port – RJ-45 Pinout
Overtemp Condition
The OmniSwitch 6250 is designed to operate within a specified operating temperature as noted under the
specifications section. However, in the event that the normal operating temperature of the switch is
exceeded, the following will occur:
Upon crossing the configured Upper Threshold, a trap will be sent. (See the OmniSwitch Network
Configuration Guide for information on configuring switch thresholds).
If the temperature continues to rise and reaches the Danger Threshold, the following will occur:
OK LED will display solid Amber.
The switch will automatically shutdown
Once the temperature drops to an acceptable operating level, the switch will automatically restart.
Check the following if an overtemp condition exists:
Verify that the switch is installed properly in an environment that adheres to the installation instruc-
tions in the following chapters.
Verify proper airflow to the chassis.
Pin Number Description
1 RX+ (-VDC)
2 RX- (-VDC)
3TX+ (+VDC)
4
5
6 TX- (+VDC)
7
8

Table of Contents