Using SNMP SNMP Overview
OmniSwitch AOS Release 6 Switch Management Guide July 2010 page 3-23
53 httpServerDoSAttackTrap httpConnection-
Stats
httpsConnec-
tionStats
webmgt This trap is sent to management
station(s) when the HTTP server
is under Denial of Service attack.
The HTTP and HTTPS connec-
tions are sampled at a 15 second
interval. This trap is sent every 1
minute while the HTTP server
detects it is under attack.
httpConnectionStats—The number of HTTP connection attempts over the past 15 seconds.
54 alaStackMgrDuplicateRoleTrap alaStack-
MgrSlotNI-
Number
alaStackMgr-
ChasRole
chassis The element identified by
alaStackMgrSlotNINumber
detected the presence of two ele-
ments with the same primary or
secondary role as specified by
alaStackMgrChasRole on the
stack.
alaStackMgrSlotNINumber—Numbers allocated for the stack NIs as follows:
- 0: invalid slot number
- 1..8: valid and assigned slot numbers corresponding to values from the entPhysicalTable
- 1001..1008: switches operating in pass through mode
- 255: unassigned slot number.
alaStackMgrChasRole—The current role of the chassis as follows:
- unassigned(0),
- primary(1),
- secondary(2),
- idle(3),
- standalone(4),
- passthrough(5).
Note: This trap is not supported on OmniSwitch 9000 switches.
55 alaStackMgrClearedSlotTrap alaStack-
MgrSlotNI-
Number
chassis The element identified by
alaStackMgrSlotNINumber will
enter the pass through mode
because its operational slot was
cleared with immediate effect.
alaStackMgrSlotNINumber—Numbers allocated for the stack NIs as follows:
- 0: invalid slot number
- 1..8: valid and assigned slot numbers corresponding to values from the entPhysicalTable
- 1001..1008: switches operating in pass through mode
- 255: unassigned slot number.
Note: This trap is not supported on OmniSwitch 9000 switches.
56 alaStackMgrOutOfSlotsTrap N/A chassis One element of the stack will
enter the pass through mode
because there are no slot num-
bers available to be assigned to
this element.
Note: This trap is not supported on OmniSwitch 9000 switches.
No. Trap Name Objects Family Description