Installation
The 8201 SIP PoE Intercom is weather protected for outdoor
installation. However if network cabling extends beyond the
perimeter of the building then adequate lightning protection is
required to protect the cabling and network switch from lightning
surges. No lightning protection is required by UL or CSA if the 8201
SIP PoE Intercom is located on the outside wall of a building and the
wiring is inside the perimeter of the building.
1. Remove the 8201 SIP PoE Intercom faceplate
2. Determine if you want a flush or surface mount installation
For surface mount:
o Discard the flush mount
gasket.
o Verify the correct orientation
of the surface mount gasket.
o Thread the wires through the
center hole, then through the
surface mount bracket.
o Fasten the surface mount
bracket at the desired location
on the wall
For flush mount:
(into an electrical box embedded in
the wall)
o Discard the surface mount
gasket and bracket.
o Slide the flush mount gasket
onto the main housing
assembly.