Important Safety Information
EMERGENCY COMMUNICATION
If used in an emergency communication application, the 8201 SIP PoE
Intercom should be routinely tested. SNMP supervision is
recommended for assurance of proper operation. Contact Algo for
other methods of operational assurance including the use of the
integrated microphone for automated “sound to air” acoustic testing.
WET OR OUTDOOR ENVIRONMENTS
The 8201 SIP PoE Intercom is intended for indoor or outdoor locations
and may be subjected to spray or weather provided the rear wiring
cavity is properly sealed to prevent water ingress.
Gaskets included with the 8201 SIP PoE Intercom may be effective
against water ingress on some, but not all surfaces in which case
additional protective measures must be taken such as a perimeter
sealant.
CAT5 or CAT6 connection wiring to an IEEE 802.3af compliant
network PoE switch must not leave the building perimeter
without adequate lightning protection.
When the Intercom is connected to wiring that exits the building,
there is potential risk of lightning induced electrical surges or high
voltages from fault conditions. To reduce risk, outdoor wiring
should be protected by Earth grounded conduit whenever possible.
Relay input and output connections must not leave the building
perimeter without adequate lightning protection.