Supported Block Transfer Messages B19
Message Operation
Fault Queue Entry Read Full reads the contents of the fault queue
specified in word 3 of the request. The response returns the fault text
which can be ASCII text. Every two characters of text are in reverse
order. Also, the 1336 FORCE drive returns a time stamp, indicating
the day and time the fault occurred.
If an error has occurred, word 1 of the response returns a negative
value.
Example
In this example, Fault Queue Entry number 3 was retrieved from a
1336 PLUS drive. The fault code for this example is 22, and the fault
name is Drive Reset Flt. The fault code (22) is word 11 (12th word) in
the decimal drive response. The fault name (Drive Reset Flt) is in the
ASCII drive response. Note that every other character is reversed.
Data File Format
* Example only These values vary depending on parameters and products.
0123456789
PLC request 3 1792 3*
Drive response
(Decimal)
12 1792 3* 29252* 20313* 8293* 25938* 25971* 8308* 27718*
8303* 22*
Drive response
(ASCII)
\00\12 \07\00 \03\00 r D v i e e R e s t l F
t \00\16
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley 1203 Series and is the answer not in the manual?

Allen-Bradley 1203 Series Specifications

General IconGeneral
Series1203
ManufacturerAllen-Bradley
Input Voltage24V DC
Operating Temperature0°C to 55°C
Housing MaterialPlastic

Related product manuals