70 Rockwell Automation Publication 1791ES-UM001G-EN-P - November 2016
Chapter 4 Wiring Examples
Figure 26 - Muting Lamp Output
In + In -
FE I0 I1 T0 T1 I2 I3 T2 T3M
PS1
L1
1
5
2
3
4
4
3
2
1
PS1
L1
1
5
2
3
4
PS1: User 24V DC Power Supply
L1: External Muting Lamp
1791ES Modules
1732ES Modules
1 - Test Output 1
2 - Input 1
3 - Input Common
4 - Input 0
5 - Test Output 0
1 - Output Power
2 - Input Power
3 - Input Common
4 - Output Common
1 - Test Output 3
2 - Input 3
3 - Input Common
4 - Input 2
5 - Test Output 2
Controller Configuration Parameter Name Configuration Setting
Test Output 3 Test Output 3 Mode Muting Lamp Output