Troubleshooting
8. Heating Element or Burner Repeatedly Cycles Off On High Limit
Thermostat
Heating element or
burner repeatedly
cycles off on high
limit thermostat
Is external exhaust
system longer than
recommended or is
there inadequate
make-up air?
Refer to
Installation
Manual for
exhaust and
make-up air
requirements.
Is lint
screen
clogged?
Remove screen
and clean. Lint
screen and
compartment
should be cleaned
after every eight
hour shift.
Is there lint
in tumbler
ducts?
Clean tumbler
ducts.
Is there lint
in external
exhaust
system?
Disassemble
exhaust
system and
clean.
Is high limit
thermostat
cycling at too
low a
temperature?
Replace
thermostat.
Is lint door
panel not
closed
properly?
Open lint door
panel, place lint
door panel back
on tumbler
ensuring a tight fit.
Is backdraft
damper not
operating?
Check for
foreign
objects, lint
accumulation
or other
possible
obstructions.
TMB1880S
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes