EasyManua.ls Logo

Alliance Laundry Systems CA050L - Motor Runs, Time on Drying Timer But No Heat

Alliance Laundry Systems CA050L
176 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
70422101 31
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Troubleshooting
19.Motor Runs, Time on Drying Timer But No Heat
Motor runs,
time on drying
timer but no
heat
Is there
power out of
temperature
control board?
Check the
ignition circuit.
Is there
power into
temperature
control board?
Check
thermistor and
cable. If OK,
replace
temperature
control board.
Is there
broken or
loose wire at
harness plug?
Repair wire.
Is there
power into
burner high
limit
thermostat?
Check for
broken wire
from airflow
switch.
TMB2268S-a
Yes
Yes
No
No
Yes
No
No
Continued on
next page.
Yes

Table of Contents

Related product manuals