Troubleshooting
27.OM Reversing Control: No Cylinder Rotation or Reversing Capabilities
208-240 Volt/60 Hertz/3 Phase and 480 Volt/60 Hertz/3 Phase Electric Models
208-240 Volt/60 Hertz/3 Phase and 460-480 Volt/60 Hertz/3 Phase Gas and Steam Models
OM Reversing
Models: No
cylinder rotation or
reversing
capabilities
Is there voltage
across the
primary of the
transformer?
Correct wiring
between
transformer
and supply
voltage. Check
fuses.
Is there voltage
across terminals 2
& 3 of the
transformer
secondary?
Replace
transformer.
Is there voltage
to the COM of
the door switch?
Correct wiring
to door switch.
Check fuses.
Is there voltage
to the N.O.
terminal of the
door switch?
Correct wiring
and check
fuses.
TMB2328S-a
Is there
voltage into
lint panel
switch?
Correct wiring
between door
switch and lint
panel switch.
Is there
voltage out of
lint panel
switch?
If actuated replace
inoperative switch.
If not actuated
adjust switch as
needed.
Is there voltage
to H2-8 terminal
of micro control?
Continue to next
step for forward
rotation or next
page for reverse
rotation.
Correct wiring
between micro
control and
door switch.
Forward
Rotation: Is
there voltage
to H2-3 of
micro control?
Make sure
unit is in the
forward portion
of rotation.
Replace micro
control.
Continued on
next page.
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes