Troubleshooting
6. Igniter Does Not Shut Off After Gas Ignition — Gas Burner
Igniter does not
shut off after
gas
ignition - gas
burner
Is tumbler not
properly equipped for
type of gas being
used?
Tumbler is equipped for
type of gas specified on
serial plate at 0-2,000
feet altitude. Refer to
Installation Manual.
Is there
insufficient gas
supply?
Open partially
closed gas shut-off
valve or correct low
gas pressure.
Is burner flame
adjusted
improperly?
Refer to
Adjustments
Section for
recommended
burner flame
adjustment.
Is electrode assembly
incorrectly installed?
Check
assembly for
correct
alignment.
Is igniter control
inoperative?
Test igniter
control and
replace if
inoperative.
Is wiring
incorrect?
Refer to wiring
diagram
located inside
contactor box.
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes