EasyManua.ls Logo

Alliance Laundry Systems DCB30CG - No Spark to Pilot Burner

Alliance Laundry Systems DCB30CG
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24 M413438
Section 3 Troubleshooting
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
24. NO SPARK TO PILOT BURNER
(Johnson Intermittent Ignition)
24 VOLTS BETWEEN
TERMINAL 2 AND
GROUND ON
ELECTRONIC
PACKAGE
YES
NO
HIGH TENSION
CABLE SECURELY
ATTACHED TO
IGNITOR POST
ARCING TO LEFT
BURNER
YES
SHIFT LEFT
BURNER FURTHER
TO LEFT
CRACKS IN
CERAMIC INSULATOR
ENCASING IGNITOR
PROBE
REPLACE
PILOT AND
ELECTRODE
ASSEMBLY
CHECK TUMBLER
HEAT CIRCUIT
CORRECT
NO
NO
YES
YES
CERAMIC INSULATOR
SECURELY BONDED
TO PILOT BURNER
ASSEMBLY
(Cannot Swivel)
REPLACE PILOT
AND ELECTRODE
ASSEMBLY
REPLACE
ELECTRONIC
PACKAGE
REPLACE PILOT
AND ELECTRODE
ASSEMBLY
7/64 INCH GAP
BETWEEN
ELECTRODE AND
LEFT DIVERTER OF
PILOT BURNER
YES
Y
E
S
N
O
NO
NO
NO

Table of Contents