EasyManua.ls Logo

Alliance Laundry Systems DCB30CG - Airflow Switch

Alliance Laundry Systems DCB30CG
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M413438 63
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
79. AIRFLOW SWITCH
a. Remove wire-way cover plate (older models),
or airflow switch box cover (newer models,
Figure 37).
b. Disconnect wires from switch. Refer to
Figure 38.
NOTE: Refer to wiring diagram when rewiring
airflow switch.
c. Remove screw(s) holding switch and mounting
bracket to rear of tumbler (older models); or to
switch box (newer models), Refer to Figure 38.
d. Remove two screws holding switch to
mounting bracket.
NOTE: After reinstalling airflow switch and
mounting bracket into switch box, adjust switch.
Refer to Adjustments section.
Figure 37
TU072-SV
WIREWAY
COVER
PLATE
DRIVE
GUARD
DRIVE
GUARD
ATTACHING
SCREW
AIRFLOW
SWITCH
SWITCH
BOX
COVER

Table of Contents

Related product manuals