EasyManua.ls Logo

Alliance Laundry Systems DCB30CG - Section 5 - Service Procedures; Control Panel

Alliance Laundry Systems DCB30CG
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M413438 33
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
Section 5
Service Procedures
IMPORTANT: References made to the left or right hand direction are taken from the operators position
facing the front of the tumbler.
34. CONTROL PANEL
a. Unlock and open access panel. To hold panel
open, swing support rod under panel. Refer to
Figure 3.
b. Coin Slide Models
(1) Remove screw holding top of escutcheon
to right side panel. Refer to Figure 1.
(2) Pull top of escutcheon forward and slide
escutcheon to the left to remove it from
hinge pin. Refer to Figure 2.
(3) Remove two screws holding control panel
to cabinet.
(4) Lift control panel off top edge of front
panel and pull it forward just far enough to
disconnect wire harness at the plug.
Figure 1
COIN
SLIDE
COIN SLIDE
ESCUTCHEON
T004se1a
ESCUTCHEON
ATTACHING SCREW
Figure 2
T003se1a
CONTROL PANEL
ATTACHING SCREWS
COIN SLIDE
HINGE
TILT
FORWARD
SLIDE TO
LEFT

Table of Contents

Related product manuals