26. SPARK TO PILOT BURNER PILOT LIGHTS NO MAIN BURNER
(Johnson Intermittent Ignition)
24 VOLTS BETWEEN
TERMINAL 3 AND
GROUND ON
ELECTRONIC
PACKAGE
YES
NO
REPLACE LEFT COIL
(Main Operator)
WIRE BETWEEN
SENSOR AND
TERMINAL 4 OF
ELECTRONIC
PACKAGE
CONNECTED
SECURELY
SENSOR SECURELY
SEATED IN
PILOT BURNER
REPLACE
SENSOR
CLEAR PILOT ORIFICE
OR REPLACE
PILOT ORIFICE
PILOT FILTER,
TUBE OR
ORIFICE
OBSTRUCTED
YES
YES
NO
YES
YES
YES
CORRECT
NO
CORRECT
YES
CRACK IN
SENSOR
CERAMIC
INSULATOR
YES
CHECK GAS
PRESSURE
NO