EasyManua.ls Logo

Alliance Laundry Systems DCB30CG - Relay (Manual Timers Models); Resistor; Cooling or Drying Timer

Alliance Laundry Systems DCB30CG
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36 M413438
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
37. RELAY (MANUAL TIMERS MODELS)
a. Remove control panel.
b. Remove two screws holding relay to bracket.
Refer to Figure 5.
c. Disconnect wires from relay.
NOTE: Refer to wiring diagram when rewiring
relay.
38. RESISTOR
(Some 208/240 Volt Models)
a. Remove control panel.
b. Disconnect resistor leads. Refer to Figure 5.
NOTE: Refer to wiring diagram when rewiring
resistor.
39. COOLING OR DRYING TIMER
a. Remove control panel.
b. Pull timer knob off timer shaft. Refer to
Figure 5.
c. Remove three screws holding timer to control
panel or mounting bracket.
d. Remove wires from timer terminal board, and
timer motor lead from terminal block.
IMPORTANT: Be sure barrier is installed in proper
position when reinstalling drying timer. Refer to
Figure 5.
NOTE: Refer to wiring diagram when rewiring
timer.
Figure 5
BRACKET
TU006-SV
DRYING
LIGHT
LOCKING
TABS
COOLING
LIGHT
TIMER
KNOB
BARRIER
TIMER
RELAY
RESISTORS
(MODELS WITH
208/240V, 60 HZ
CONTROL

Table of Contents