M413438 43
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
48. TRANSFORMER
(Automatic Pilot Ignition Models)
a. Remove control panel.
b. Disconnect transformer wires at electronic
package. Refer to Figure 16.
c. Disconnect remaining wires from transformer
at connectors.
NOTE: Refer to wiring diagram when rewiring
transformer.
d. Remove nut holding transformer to cabinet.
Refer to Figure 16.
Figure 16
T015se1a
ELECTRONIC
PACKAGE
TRANSFORMER
NUT
CONNECTORS

Table of Contents