Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
46. COIN SLIDE
a. Unlock and open access panel. Use support rod
to hold panel up.
b. Disconnect accumulator wire harness at plug.
c. Unlock service door on top of meter case.
d. Lift service door. Remove door, accumulator,
mounting bracket and wire harness from
tumbler.
e. Remove two capscrews holding accumulator
bracket to service door. Refer to Figure 12.
f. From back side of tumbler, remove screw
holding coin slide assembly to bracket on inside
of meter case. Refer to Figure 12.
g. Remove coin slide assembly.
47. CONTROL THERMOSTAT
a. Remove control panel.
b. Pull knob off thermostat. Refer to Figure 13.
c. Disconnect wires from thermostat.
d. Remove two screws holding thermostat to
bracket.
e. Remove wire-way attaching screws. Refer to
Figure 14.
f. Remove screws, wire clips and/or retaining
straps securing thermostat sensing tube in wire-
way.
g. Later Models: Remove junction box cover
attaching screws. Refer to Figure 14.
IMPORTANT: When reinstalling thermostat, be
sure to install all screws and wire clips and replace
all retaining straps removed in steps f and g.
h. Unlock and remove lint panel.
i. Spread locking tabs on sensing probe bracket
and disengage probe from bracket. Refer to
Figure 15.
IMPORTANT: When reinstalling thermostat, be
sure to secure sensing probe with locking tabs on
bracket.
j. Carefully remove thermostat, tube and probe.
Figure 12
T011se1a
BRACKET
SCREW
COIN SLIDE
ASSEMBLY
Figure 13
PHILLIPS HEAD
SCREWS
T012SE1A
THERMOSTAT
KNOB
THERMOSTAT
BRACKET
SENSING
TUBE