48 M413438
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
55. GAS VALVE
(Johnson Controls Glow-Bar Models)
a. Remove control panel.
b. Close gas shut-off valve. Refer to Figure 21.
c. Disconnect all wires from gas valve terminals
and disconnect gas valve pipe unions.
d. Remove screws holding gas valve and bracket
to stove assembly.
e. Remove nipple from left side of valve and plug
from right side of valve.
NOTE: Refer to wiring diagram when rewiring gas
valve.
IMPORTANT: When reinstalling gas valve, use
pipe compound resistant to action of L.P. gas on all
pipe threads.
56. MAGNETIC OPERATORS
(Johnson Controls Glow-Bar Models)
a. Remove control panel.
b. Close gas shut-off valve. Refer to Figure 21.
c. Disconnect wires from magnetic operator
terminals.
d. Remove screws holding magnetic operators to
gas valve body, Refer to Figure 19.
NOTE: Refer to wiring diagram when rewiring
magnetic operators.
Figure 21
PIPE
UNION
GAS
SHUT-OFF
VALVE
(Shown in the
ON Position)
T018SE3B
SENSOR
JOHNSON CONTROLS GLOW-BAR
IGNITION BURNER
GLOW-BAR
IGNITER
To reduce risk of fire or explosion, check
pipe connections for gas leaks with a non-
corrosive leak detection fluid. Do not use an
open flame to check for gas leaks!
W310
WARNING