Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
44. ACCUMULATOR (COIN SLIDE MODELS)
a. Unlock and open access panel. Use support rod
to hold panel up.
b. Disconnect accumulator wire harness at plug.
Refer to Figure 10.
c. Unlock service door on top of meter case.
d. Lift service door. Remove door, accumulator,
mounting bracket and wire harness from
tumbler.
IMPORTANT: Be careful not to damage wires or
thermostat sensing tube when lifting service door
off of meter case ( or when reinstalling).
e. Remove two capscrews holding accumulator
bracket to service door. Refer to Figure 10.
f. Remove two screws holding accumulator
assembly to bracket. Refer to Figure 10.
Figure 10
T009SE1B
ACCUMULATOR
ACCUMULATOR
WIRE HARNESS
PLUG
SERVICE
DOOR
MOUNTING
BRACKET
METER
CASE