Electrical Requirements
65
70458301ENR6
T45 Series Gas Models (Total Machine)
9 kW 025 Series Electric Models
Table 12
12 kW 025 Series Electric Models
Table 13
Serial Plate Voltage
Terminal Block
Connections Required
Serial Plate
Amps
Recommended Circuit
Breaker Rating
Wire Size
AWG (mm
2
)
208-240V/60Hz/1ph
L1, L2, Neutral, and ground 12.0 15A – 2 pole 14 (2.5)
230V/50Hz/1ph
L1, Neutral and ground 10.2 15A – 1 pole 14 (2.5)
200V/50Hz or 60Hz/1ph
L1, Neutral and ground 11.2 15A
– 1 pole 14 (2.5)
230-240V/50Hz/1ph
L1, Neutral and ground 10.8 15A – 1 pole 14 (2.5)
200-208V/60Hz/3ph
L1, L2, L3, and ground 9.6 15A
* – 3 pole 14 (2.5)
240V/60Hz/3ph
L1, L2, L3, and ground 9.6 15A
* – 3 pole 14 (2.5)
* 3 Phase machines should not have fuses, breakers only.
Table 11
Serial Plate Voltage
Terminal Block
Connections Required
Serial Plate Amps Recommended Circuit
Nonreversing Reversing Breaker Rating
Wire Size
AWG (mm
2
)
400V/50Hz/3ph
L1, L2, L3, and ground 16 N/A 20A* – 3 pole 12 (4)
* 3 Phase machines should not have fuses, breakers only.
N/A = Not Applicable
Serial Plate Voltage
Terminal Block
Connections Required
Serial Plate Amps Recommended Circuit
Nonreversing Reversing Breaker Rating
Wire Size
AWG (mm
2
)
208V/60Hz/1ph
L1, L2, Neutral, and ground 64 N/A 80A – 2 pole 4 (25)
240V/60Hz/1ph
L1, L2, Neutral, and ground 57 N/A 80A – 2 pole 4 (25)
200V/50Hz/1ph
L1, Neutral, and ground 63 N/A 80A – 1 pole 4 (25)
200V/60Hz/1ph
L1, L2 and ground 64 N/A 80A – 2 pole 4 (25)
230-240V/50Hz/1ph
L1, Neutral, and ground 58 N/A 80A – 1 pole 4 (25)
200-208V/60Hz/3ph
L1, L2, L3, and ground 37 37 50A* – 3 pole 6 (16)
200V/50Hz/3ph
L1, L2, L3, and ground 36 36 50A* – 3 pole 6 (16)
230-240V/50Hz/3ph
L1, L2, L3, and ground 33 N/A 50A* – 3 pole 6 (16)
240V/60Hz/3ph
L1, L2, L3, and ground 33 33 50A* – 3 pole 6 (16)
380V/50 or 60Hz/3ph
L1, L2, L3, and ground 20 20 25A* – 3 pole 10 (6)
400-415V/50Hz/3ph
L1, L2, L3, and ground 18 18 25A* – 3 pole 10 (6)
440V/60Hz/3ph
L1, L2, L3, and ground 17 N/A 25A* – 3 pole 10 (6)
460-480V/60Hz/3ph
L1, L2, L3, and ground 16 16 25A* – 3 pole 10 (6)
* 3 Phase machines should not have fuses, breakers only.
N/A = Not Applicable

Table of Contents

Other manuals for ALLIANCE 030 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ALLIANCE 030 Series and is the answer not in the manual?

ALLIANCE 030 Series Specifications

General IconGeneral
BrandALLIANCE
Model030 Series
CategoryDryer
LanguageEnglish

Related product manuals