AT-9000 Switch Command Line User’s Guide
1001
NO SNMP-SERVER
Syntax
no snmp-server
Parameters
None
Mode
Global Configuration mode
Description
Use this command to disable SNMPv1, SNMPv2c, and SNMPv3 on the
switch. The switch does not permit remote management from SNMP
applications when SNMP is disabled. It also does not send SNMP trap or
inform messages.
Confirmation Command
“SHOW SNMP-SERVER” on page 1008.
Example
This example disables SNMPv1, SNMPv2c, or SNMPv3 on the switch:
awplus> enable
awplus# configure terminal
awplus(config)# no snmp-server

Table of Contents

Other manuals for Allied Telesis AT-9000/28SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AT-9000/28SP and is the answer not in the manual?

Allied Telesis AT-9000/28SP Specifications

General IconGeneral
Number of Ports28
Port TypeGigabit Ethernet
Ports24 x 10/100/1000Base-T, 4 x SFP
Switching Capacity56 Gbps
Forwarding Rate41.7 Mpps
Power over Ethernet (PoE)No
Rack MountableYes
Product TypeSwitch
Layer3
MAC Address Table Size16K
VLANs4K
Jumbo Frames9K
Dimensions (W x D x H)440 x 240 x 44 mm
Power SupplyAC 100-240V, 50/60Hz
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 70°C
Humidity10% to 90% (non-condensing)

Related product manuals