Chapter 50: GARP VLAN Registration Protocol Commands
788
GVRP TIMER LEAVEALL
Syntax
gvrp timer leaveall
value
Parameters
value
Specifies the Leave All Timer in centiseconds. The range is 500 to
3000 centiseconds. The default is 1000 centiseconds.
Mode
Global Configuration mode
Description
Use this command to set the GARP Leave All timer.
Note
The settings for this timer must be the same on all GVRP-active
network devices.
Example
This command sets the Leave All timer to 10 seconds:
awplus> enable
awplus# configure terminal
awplus(config)# gvrp timer leaveall 1000