Alpha XM2-300HP - Menu Structure and Navigation (from Active Alarms Screen)

Alpha XM2-300HP
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.0 Operation, continued
4.3 Smart Display modes for XM2-300HP, continued
4.3.5 Menu Structure and Navigation (from Active Alarms screen)
Auto-Scroll Information
To Operation Normal
(Auto-scroll Information)
OPERATION NORMAL
OPERATION NORMAL
(Single-step Information)
Back to
Auto-Scroll
<ESC>
LEGEND
Description
SETUP MENU
(Auto-scroll Information)
Back to
Auto-scroll
To
Single-step
Sample Active
Alarm
To Single-step
Help Screens
Back to Auto-Scroll
To Single-step
To Active Alarms
***ACTIVE ALARMS***
(Auto-scroll Information)
Self Test Fail
Low Batt Volts
High Batt Volts
No Batteries
Batt Temp Probe
Line Isolation
Output Failure
Output Overload
Output 1 Tripped
Output 2 Tripped
Charger Failure
Input Failure
Inv Disconnected
Inverter Temp
Tap Fuse Fail
Config Error
N+1 In Use
N+1 Fault
***ACTIVE ALARMS***
Single-step Information
Output Overload
Single-step Information
1. Output Short Ckt?
2. Too Much Load
3. Chk Output Current
COMMS INFO
Float V/C = 2.27 V
SETUP MENU
CODE VER = 7.01.0
DEVICE ADDRESS= 1
ALPHACELL = OTHER
FLOAT V/C=2.27
ACCEPT V/C=2.40
TEMP COMP=5mV
BATT CAPACITY=100Ah
# BATT STRINGS*
BATT 1 DATE M/Y
BATT 2 DATE M/Y**
BATT 1 MHOS
BATT 2 MHOS**
MHO 1 DATE M/Y
MHO 2 DATE M/Y**
BATTERY 1 LIFE
BATTERY 1 AGE
BATTERY 2 LIFE**
BATTERY 2 AGE**
MHO’S MIN LEVEL
MHO’S MAJ LVL
STANDBY TIME=65M
STANDBY EVENTS=12
TOTAL RUN TIME = 365D
SELF TEST = OFF
TEST INTERVAL
TEST INHIBIT
%DISCHARGE
TEST DURATION = 10M
TEST COUNTDOWN
FREQ RANGE = 3.0Hz
PIM OPTION = YES
RESET OUT 1
RESET OUT 2
OVER CURR 1 = 15.0A
OVER CURR 2 = 15.0A
RETRY DLY = 60s
RETRY LMT
OVER CURR TOL = 3000
SYSTEM FAN*
HEATER MAT*
PS PRIORITY*
TECHNICIAN ID*
INPUT LIMIT*
SET DEFAULTS
SELECT LANGUAGE
OPER MODE = LINE
BATT STATUS
INV STATUS
DPM STATUS
INPUT VOLTAGE 120V
INPUT FREQUENCY 60Hz*
INPUT CURRENT
INPUT WATTS
OUTPUT VOLTAGE 89V
OUTPUT 1 CURR
OUTPUT 2 CURR
OUTPUT WATTS
OUTPUT VA 1060*
PERCENT LOAD 80%
CHARGER MODE = FLOAT
BATT VOLTAGE 40.5V
BATTERY TEMP 37°C
ENCLOSURE TEMP
CHARGER CURRENT 8.2A
EST. BATT RUN
12 EVENTS 65 MIN
COMMS INFO
(Single-step Information)
To Single-step
(Single-step Information)
(Auto-scroll Information)
Back Auto-scroll
To
Program Mode
To Accept New Data
To Accept New Data
To Abort
Edit using
Control
Panel
Key
Display
Symbol
UP Arrow
DOWN Arrow
ESCAPE
ENTER
Back to Single-step
Setup Menu
Output Overload
Auto-scroll Information
1. Output Short Ckt?
2. Too Much Load
3. Chk Output Current
Sample Active
Alarm
Back to Auto-scroll
Help Screens
To Help screens
for selected alarm
Self Test Fail
Low Batt Volts
High Batt Volts
No Batteries
Batt Temp Probe
Line Isolation
Output Failure
Output Overload
Output 1 Tripped
Output 2 Tripped
Charger Failure
Input Failure
Inv Disconnected
Inverter Temp
Tap Fuse Fail
Config Error
N+1 In Use
N+1 Fault
OPER MODE = LINE
BATT STATUS
INV STATUS
DPM STATUS
INPUT VOLTAGE 120V
INPUT CURRENT
INPUT WATTS
OUTPUT VOLTAGE 89V
OUTPUT 1 CURR
OUTPUT 2 CURR
OUTPUT WATTS
PERCENT LOAD 80%
CHARGER MODE = FLOAT
BATT VOLTAGE 40.5V
BATTERY TEMP 37°C
ENCLOSURE TEMP
CHARGER CURRENT 8.2A
EST. BATT RUN
12 EVENTS 65 MIN
CM 00:90:EA:12:34:56
CPE 00:90:EA:12:34:57*
CM 192.168.123.123
CPE 192.168.123.124*
CM Rx PWR -12.9 dBmV
CM Tx PWR 34.5 dBmV
DN FREQ 300.000 MHz
UP FREQ 15.000 MHz
MODEL DPM
SW xx.xx.xx.xx
*Only visible when in
single-step mode
Back to
Auto-scroll
To
Single-step
To Setup Menu
Back to
COMMS Info
To
COMMS Info
Back to
Operation Normal
CM 00:90:EA:12:34:56
CPE 00:90:EA:12:34:57*
CM 192.168.123.123
CPE 192.168.123.124*
CM Rx PWR -12.9 dBmV
CM Tx PWR 34.5 dBmV
DN FREQ 300.000 MHz
UP FREQ 15.000 MHz
MODEL DPM
SW xx.xx.xx.xx
* only shown in
Dual-IP configurations
Pressing ENTER enables
the user to select the AlphaCell
battery in the system.
Values for Float, Accept,
Temp Comp and Battery
Capacity are automatically
selected.
220GOLD
220HPL-FT
220GXL
210GXL
195GXL
195GOLD
180GXL
165GXL
115HPL-FT
85GXL
70HPL-FT
CODEVER = 7.01.0
DEVICE ADDRESS = 1
ALPHACELL=OTHER
FLOAT V/C = 2.27
ACCEPT V/C = 2.40
TEMP COMP=5mV
BATT CAPACITY = 100Ah
BATTERY1 DATE
BATTERY1 MHOS
MHO1 DATA
BATTERY1 LIFE
BATTERY1 AGE
MHO’s MIN LVL
MHO’s MAJ LVL
STANDBY TIME=65M
STANDBY EVENTS=12
TOTAL RUN TIME=365D
SELF TEST = OFF
TEST INTERVAL
TEST INHIBIT
% DISCHARGE
TEST DURATION = 10M
TEST COUNTDOWN
FREQ RANGE = 3.0Hz
PIM OPTION = YES
RESET OUT 1
RESET OUT 2
OVERCURRENT1 = 15.0A
OVERCURRENT2 = 15.0A
RETRY DELAY = 60S
RETRY LIMIT = 20
OVERCURRENT TOL = 3000
SYSTEM FAN
HEATER MAT
PS PRIORITY
TECH ID
INPUT I LIMIT
SET DEFAULTS = NO
SELECT LANGUAGE
Selection returns to
Single-Step
Set-Up Menu
LANGUAGE =
ENGLISH
SPANISH
FRENCH
GERMAN
**Visible when “Number of Battery
Strings” is set to 2.
*Visible in Single-step
43