6.3.9 Adjusting the fan speed
REQUIREMENTS
The hopper is full
The hopper is closed
WARNING
Risk of injury due to parts of the fan being
flung out
If the fan is operated at excessive speeds, fan
parts can break and be flung out.
Make sure that the fan speed does not
exceed 5,000 1/min.
NOTE
The specifications for the fan speed are
recommendations.
< = 150 kg/ha
>
150 kg/ha
3200
4000 4000
4500
max. 5000 min
-1
min
-1
ME1515
12
3
CMS-I-00004431
1. Read the fan speed for fertiliser
, seed
or
fine seeds
from the table.
2. If seed remains in the hose package or a cyclone
separator is used:
Increase the fan speed
or
If seed is blown out of the seedbed:
Reduce the fan speed.
CMS-T-00003208-G.1
6 | Preparing the machine
Preparing the implement for operation
MG6492-EN-II | P.1 | 21.11.2023 | © AMAZONE
71