Before the T-Pack F can be disconnected from the
FTender:
Remove the transport lock from the FTender
Remove the working position sensor from the T-
Pack F
Dismount the T-Pack F from the FTender
Install the lower link mountings on the FTender
Install the working position sensor on the FTender
Install the T-Pack F transport lock
1. To dismount the transport lock from the
FTender:
Remove the linch pin
1
.
1
CMS-I-00003640
2. Remove the nuts and washers
3
.
3. Remove the locking plate
2
.
4. Remove the bolts
1
.
3
2 1
CMS-I-00003639
6 | Preparing the machine
Preparing the implement for operation
MG6492-EN-II | P.1 | 21.11.2023 | © AMAZONE