Version 2.12 ©Copyright 2020, Ambient LLC. All Rights Reserved. Page 3
home.
Warning: Installing your weather station in a high location may result in injury or death.
Perform as much of the initial check out and operation on the ground and inside a building or home.
Only install the weather station on a clear, dry, day.
3. Quick Start Guide
Although the manual is comprehensive, much of the information contained may be intuitive. In
addition, the manual does not flow properly because the sections are organized by components.
The following Quick Start Guide provides the necessary steps to install and operate the weather
station, and upload to the internet, along with references to the pertinent sections.
Set Up
Step
Description
Section
1
Assemble and power up the sensor array
5.3
2
Power up the display tablet and synchronize with sensor array
5.6
3
Mount the sensor array
5.3.6
4
Set date and time on tablet
6.7.1
5
Calibrate the relative pressure to sea-level conditions (local airport) on tablet
6.9
6
Reset the rain to zero on tablet
6.9
Wi-Fi and Internet
7
Configure Wi-Fi
6.7.16
8
Register and upload to Weather Servers
6.7.15
4. Pre-Installation Checkout and Site Survey
4.1 Pre Installation Checkout
Before installing your weather station in the permanent location, we recommend operating the weather
station for one week in a temporary location with easy access. This will allow you to check out all the
functions, ensure proper operation and familiarize you with the weather station and calibration
procedures.
4.2 Site Survey
Perform a site survey before installing the weather station. Consider the following:
1. You must clean the rain gauge every few months and change the batteries every 2-3 years.
Provide easy access to the weather station.
2. Avoid radiant heat transfer from buildings and structures. In general, install the sensor array at
least 5’ from any building, structure, ground, or roof top.
3. Avoid wind and rain obstructions. The rule of thumb is to install the sensor array at least four
times the distance of the height of the tallest obstruction. For example, if the building is 20’
tall and the mounting pole is 6’ tall, install the sensor array 4 x (20 6) = 56’ away.
4. Mount the sensor array in direct sunlight for accurate temperature readings.
5. Installing the weather station over sprinkler systems or other unnatural vegetation may affect
temperature and humidity readings. We suggest mounting the sensor array over natural
vegetation.
6. Wireless Range. Radio communication between receiver and transmitter in an open field can
reach a distance of up to 330 feet, providing there are no interfering obstacles such as
buildings, trees, vehicles and high voltage lines. Wireless signals will not penetrate metal

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ambient Weather WS-2000 and is the answer not in the manual?

Ambient Weather WS-2000 Specifications

General IconGeneral
Display TypeColor LCD
ConnectivityWi-Fi
Power Source (Console)AC Adapter
Transmission Frequency915 MHz
Data LoggingYes
Indoor Temperature Range32°F to 140°F (0°C to 60°C)
Indoor Humidity Range10% to 99%
Outdoor Humidity Range10% to 99%
Wind Direction0° to 360°
UV Index Range0 to 15
Console DisplayColor
Sensors IncludedTemperature, Humidity, Wind Speed, Wind Direction, Rainfall, UV, Solar Radiation
Power Source (Sensor Array)Solar Panel with Battery Backup
Outdoor Sensor RangeUp to 330 feet (100 meters)
Transmission RangeUp to 330 ft (100 m) line of sight
Update Rate16 seconds
Data Update Interval16 seconds
Outdoor Temperature Range-40°F to 140°F (-40°C to 60°C)
Rainfall Accuracy+/- 5%
Rainfall Range0 to 393.7 inches (0 to 9999 mm)
Wind Speed Range0 to 100 mph (0 to 160 km/h)
Solar Radiation Range0 to 1800 W/m²