MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)
16 of 30
Table 5: Monitor Arming Codes
Code # Display / Queuing / Clearance Code
1 Single / Sequence / Instant SSI
2 Single / Sequence / Auto SSA
3 Single / Sequence / Manual SSM A
4 Single / Hold / Instant SHI
5 Single / Hold / Auto SHA
6 Single / Hold / Manual SHM A
7 Block / Sequence / Instant BSI
8 Block / Sequence / Auto BSA
9 Block / Sequence / Manual BSM A
10 Block / Hold / Instant BHI
11 Block / Hold / Auto BHA
12 Block / Hold / Manual BHM A
13 (h) Dual / Hold / Instant DHI
13 (s) Dual / Sequence / Instant DSI
14 (h) Dual / Hold / Auto DHA
14 (s) Dual / Sequence / Auto DSA
15 (h) Dual / Hold / Manual DHM A
15 (s) Dual / Sequence / Manual DSM A
16 Disarm Monitor DIS
Note: If a dual display code [13-15] is selected, the
second (sequence) monitor is automatically
selected after the first (hold) monitor is armed. The
sequence monitor number will always equal the hold
monitor number + 1.
To arm a monitor:
1. Call the monitor to be armed.
2. Turn the keyswitch to the PROGRAM position.
3. Select the desired arming code from the table
above, and enter the code number (1-15) on the
numeric keypad.
4. Press the ARM key in the keyboard’s MONITOR
section. The code letters will be displayed for five
seconds in the on-screen status line.
Note: Monitor arming can be verified at any time, by
pressing the ARM key. The arming code letters will
be displayed for five seconds in the status line. If the
monitor is not armed the code “DIS” will be
displayed.
Option for Manual Clearance
Any monitor assigned for instant or auto clearance
can be additionally enabled for manual clearance.
To enable or disable manual clearance:
1. Call the desired armed monitor.
2. Turn the keyswitch to the PROGRAM position.
3. Do one of the following:
Command Function
17 ARM
Enable manual clearance
18 ARM
Disable manual clearance
4. Press the ARM key.
Any monitor armed for manual clearance will display
a four-letter code acronym with “A” (acknowledge)
as its fourth or right-most code letter.
Disarming a Monitor
1. Clear all currently active alarms.
2. Call a currently armed monitor.
3. Turn the keyswitch to the PROGRAM position.
4. Enter 316 and press F2 to disarm the monitor.