MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)
30 of 30
Changing Keyboard Priority Levels
1. Move the cursor to the KEYBOARD menu item.
2. Use the numeric keypad to enter the desired
keyboard number (1-32), and press the Enter
(Preset) key. The cursor moves to the
PRIORITY LEVEL menu item.
3. Use the numeric keypad to enter the Priority
Level (1-8), and press the Enter (Preset) key to
save.
Note: Priority levels are individually configurable.
In general, “8” should represent the highest
priority level; “1” should represent the lowest
priority level. Keyboards with higher priority
levels can capture control of cameras from
keyboards with lower priority levels.
4. When finished making changes, press Exit
(Patrn) to return to the previous menu.
Configuring Priority Settings
If Priority is selected from the Users/Keyboards
menu, the following menu is displayed:
PRIORITY
LEVEL 1
ADD USER Y
SYSTEM RESET Y
LOCK CAM ABILITY Y
OVERRIDE N
MENU ACCESS Y
CHANGE PARAMETERS Y
PREVIOUS MENU
Use this menu to configure settings associated with
adding users, resetting the system, locking
cameras, override, menu access, and changing
system parameters for each of the 8 priority levels.
To configure a Priority Level:
1. Move the cursor to the LEVEL menu item.
2. Use the numeric keypad to enter the priority level
number (1-8), and press the Enter (Preset) key.
3. Move the cursor to the menu item you want to
change. Press the Enter (Preset) key to change
the setting. The available setting for each menu
item is Y (enabled) or N (disabled). The following
settings can be configured:
Add User: If enabled (Y), the selected priority
level can add new users. If disabled (N), the
selected priority level cannot add new users.
Note: The USER IDs setting must be enabled
for the Add User setting to apply.
System Reset: If enabled (Y), the selected
priority level can reset the system by keyboard
commands. If disabled (N), the selected priority
level cannot reset the system by keyboard
commands.
Lock Cam Ability: If enabled (Y), the selected
priority level can lock the control of a camera by
keyboard commands. If disabled (N), the
selected priority level cannot lock the control of a
camera by keyboard commands.
Override: If enabled (Y), the system uses
partitioning tables to provide or deny access to
camera view and/or control, and the selected
priority level cannot override the partitioning. If
disabled (N), the selected priority level can
override the keyboard/camera view and control
partitioning restrictions.
Menu Access: If enabled (Y), the selected
priority level has access to the programming
menus through the keyboard. If disabled (N), the
selected priority level does not have access to
the programming menus through the keyboard.
Note: Menu Access must be enabled to access
the Change Parameters setting.
Change Parameters: If enabled (Y), the
selected priority level can change system data
through the menus. If disabled (N), the selected
priority level cannot change system data through
the menus.
Note: If Menu Access is disabled for the
selected priority level, Change Parameters is
automatically disabled and cannot be changed.
4. When finished making changes, press Exit
(Patrn) to return to the previous menu.