MEGAPOWER 168 / AD2088 OPERATION AND PROGRAMMING REFERENCE GUIDE (8200-0170-01, REV. A)
19 of 30
Audio Alarm Programming
The AD2088 keyboard can be programmed to
provide an audio tone when an alarm is received at
an armed monitor under keyboard control. The
system default setting is audio enabled (ON) for all
system keyboards. Audio alarm signals can be
enabled or disabled through a keyboard, a keyboard
port, or system wide.
Enabling/Disabling Keyboard Port Audio
Alarms
To enable/disable an audio alarm for a keyboard
port (up to four individual keyboards):
1. Turn the keyswitch to the PROGRAM position.
2. Do one of the following:
Command Function
48 F2
Enables audio alarms for the
keyboard port
47 F2
Disables audio alarms for the
keyboard port
System Wide Audio Alarm Programming
To enable/disable audio alarm for all keyboard
ports:
1. Turn the keyswitch to the PROGRAM position.
2. Do one of the following:
Command Function
46 F2
Enables audio alarms for all
keyboard ports
45 F2
Disables audio alarms for all
keyboard ports