21. When the system is completely drained, repeat steps 9 .
through 16 to flush
the
system with fresh water.
Be
sure
to run water through each faucet for several minutes to
thoroughly flush out the solution.
22.
Fill the water tank,
if
desired. The system is now
ready"
to
use.
THE WATER
PUMP
r-
The on-board fresh water system is pressurized by a self-priming, 12-volt
DC pump. The pump operates automatically when the pump power switch is
ON
and a faucet is opened. When the faucets are closed, the pump shuts off
..
At free flow, the pump draws approximately
7to
7
1
/z
amps, and can run dry
for extended periods without damage. A IS-amp fuse in the panel board
(located at the foot
of
the bed) protects the water pump/water heater circuit.
See
"ELECTRICAL
SYSTEMS."
Tum
the pump master switch ON to pressurize the system. When a faucet
is opened after the initial filling
of
the tank, the
water
may sputter for a few
seconds. This is normal and is not
cause
for concern. The water flow will
stabilize when all air is bled from the water lines.
WATER FILTER
Dirt, mineral
scale,and
organic matter are filtered ·out
of
the fresh water
system by
an
in-line water filter on the inlet side
of
tfie water pump.
If
you
suspect a clogged filter,
it