Maintenance | 6-9
32
202
rw
uint
ALYTE2RES
254
2
Decimal places to use for displaying
analyte 2
203
rw
boolean
RELAY1NC
256
1
Normally closed indicator for relay 1.
1=Normally closed, 0=Normally open
204
rw
boolean
RELAY2NC
257
1
Normally closed indicator for relay 2.
1=Normally closed, 0=Normally open
205
rw
boolean
RELAY3NC
258
1
Normally closed indicator for relay 3.
1=Normally closed, 0=Normally open
206
rw
boolean
RELAY4NC
259
1
Normally closed indicator for relay 4.
1=Normally closed, 0=Normally open
207
rw
uint16
MENUTO
260
1
Menu timeout. The time that the menu
will navigate to the homescreen after
no activity. 0 is disabled
208
rw
uint16
PWDTO
261
1
Password timeout. The time that a
user logged into the front display
menu will be logged out after no
activity. 0 is disabled
209
r
uint
SYSWARN1
262
2
Temporary cache to miror warnings in
SYSALARM1
210
r
uint
SYSWARN2
264
2
Temporary cache to miror warnings in
SYSALARM2
211
r
uint
SYSSTWARN
266
2
system statuc warning
212
rw
uint16
PTSEED
268
1
TheseedvalueforallIIRfilters.
213
rwf
float
MAXTEMP_2
269
2
MaxTECtemperature2
214
rwf
float
MINTEMP_2
271
2
MinTECtemperature2
215
rw
float
REFCONC_2
273
2
ConcentrationofReferencecall
216
rwf
int16
STATICPT
275
1
Pressure(STCELLP)andtemp
(STCELLT)staticvalueusage.
0=neither, 1=use static pressure,
2=use static temperature, 3= use both
217
rwf
float
STCELLT
276
2
Static cell temperature. Use by
settingSTATICPTto2or3
218
rwf
float
STCELLP
278
2
Static cell pressure. Use by setting
STATICPTto1or3
219
rw
int16
ANAOUT1H
280
1
Analogoutput1,0- follow source
during cal, 1 - hold output during cal
220
rw
int16
ANAOUT2H
281
1
Analogoutput2,0- follow source
during cal, 1 - hold output during cal
L82
221
rwf
float
LASTH_2
282
2
Threshold in 2f signal
222
rwf
float
LASREFPWR_2
284
2
ReferenceLaserPower(powerat
calib)
223
rwf
float
LASTS_2
286
2
LaserSamplePeriodinseconds
224
rwf
float
LASPWR_2
288
2
LaserPower
225
rwf
float
CELLLENGTH
290
2
Cell length, concentrations are
multiplied by this parameter
226
r
int16
DIAGS
292
1
Used to change state to diagnostics
from the menu
227
rw
float
CONCMIN_2
293
2
Minimum Concentration
228
rw
float
CONCMAX_2
295
2
Maximum Concentration
229
rwf
int16
PASSCODE
297
1
PASSCODEtochangesystem
params
230
rwf
float
LASTH
298
2
Threshold in 2f signal
231
rwf
float
LASREFPWR
300
2
ReferenceLaserPower(powerat
calib)
232
rwf
float
LASTS
302
2
LaserSamplePeriodinseconds
233
rwf
float
LASPWR
304
2
LaserPower
33
234
rwf
float
REFREFCONC
306
2
Referenceconcentrationofthe
reference cell at
235
rw
boolean
PPSRC
308
1
if FALSE,usestaticpressure
236
rw
float
PPMAX
309
2
Max Pressure allowed in PPMV to
Dew Point
237
rw
float
PPMIN
311
2
Min Pressure allowed in PPMV to
Dew Point
238
rwf
boolean
UAIFORM
313
1
Selects0offsetformulaifTRUEelse
selects4mAoffsetformula for User
AnalogInput
239
rwf
float
REFCONCTOL
314
2
Referenceconcentrationalarmband
(%)
240
rwf
float
REFCONCTOL_2
316
2
Referenceconcentrationalarmband
2(%)
241
rwf
float
BGNDFACTOR
318
2
Background compensation factor
242
rwf
float
BGNDNORMTEMP
320
2
Background compensation
temperature
243
r
float
CELLPRESD
322
2
UserAnalogInput1output(engr
units)
244
r
float
PRESST
324
2
Transmiter Pressue
245
rw
float
PRESSTS
326
2
UserAnalogInput1Span
246
rw
float
PRESSTOS
328
2
UserAnalogInput1Offset
247
rwf
float
PRESSTIIR
330
2
TransmiterPressueIIRFilterWeight
248
rw
float
FIXEDPRES
332
2
UserAnalogInputFixedSubstitute
Value
249
rwf
float
CELLTEMPIIR
334
2
CellRTD1IIRFilterWeight
250
rwf
float
REFTEMP
336
2
RTD2(referencecelltemperature)
251
rwf
float
REFTEMPIIR
338
2
RTD2AnalogInputFilterWeight
252
r
float
ALYTE1CON_UC
340
2
Unclamped analyte 1 concentration
value
253
r
float
ALYTE2CON_UC
342
2
Unclamped analyte 2 concentration
value
254
r
float
CELLPRES
344
2
PRESX1AnalogInputFilteredvalue
255
rwf
float
CELLPRESS
346
2
Pressure Transducer 1 Scale
256
rwf
float
CELLPRESOS
348
2
PressureTransducer1Offset
257
rwf
float
CELLPRESIIR
350
2
PRESX1IIRfilterweight
258
rwf
float
TECIIR
352
2
TECIIRFilterWeight
259
r
float
UNUSEDHTR1
354
2
(Notused)
260
rwf
float
UNUSEDHTR1S
356
2
(Notused)
261
rwf
float
UNUSEDHTR1OS
358
2
(Notused)
262
r
float
UNUSEDHTR2
360
2
(Notused)
263
rwf
float
CONCOUTH1
362
2
Concentration out of range Hight 1
264
rwf
float
CONCOUTL1
364
2
ConcentrationoutofrangeLow1
265
r
float
UNUSEDHTR3
366
2
(Notused)
266
rwf
float
CONCOUTH2
368
2
Concentration out of range Hight 1
267
rwf
float
CONCOUTL2
370
2
Concentration out of range Low1
268
rwf
int16
WLTOL1
372
1
Wavelength Tolerance 1
269
rwf
int16
WLTOL2
373
1
Wavelength Tolerance 2
270
rwf
float
IOFFSET
374
2
Injection current offset
271
rwf
float
LSTWLRES
376
2
Temperature Wavelength resolution
272
rwf
int16
MEDSIZE
378
1
Median filter size
273
rw
float
CONCMIN
379
2
Minimum Concentration
274
rw
float
CONCMAX
381
2
Maximum Concentration
275
r
int16
CTRINDX
383
1
Spectrum center index
276
rwf
float
TEMPREF
384
2
Referencetemperatureforthisdiode
277
rwf
int16
CONCSTART
386
1
Starting point of concentration window
278
rwf
int16
CONCEND
387
1
Endpointofconcentrationwindow
279
rwf
int16
CONCPEAK
388
1
Peak index for linklock

Table of Contents