AMETEK CTS AMP 200N series
Manual for Operation V 4.0.3 29 / 60
12 Application
The AMP 200N is a multi using instrument with a large number of applications. In general the AMP 200N can be
used for the following two groups of application:
A : Immunity tests
Different devices like Radiating loop or Coupling Network (CN200) are connected to the Test supply
output. Therefore it is mandatory to use the AMP 200N set the output voltage to 0V
B: DC source
The AMP 200N is used as an additional DC source with the alternator voltage 13.5V or higher voltage..
Output Range
The AMP 200N series has as class A amplifier two. See technical specifications for the various models.
12.1 Using Capacitive loads
AMP 200N
An additional L/R Network,
L5uH parallel 10, is proposed to
connect in series to the AMP200
output. This netwok will prevent
the swinging of the AMP regulation
control.
AMP 200N1.1
The AMP 200N1.1 has already
built in the L/R networkinside the
device.
Use the software Device Setup
for activate the R/L Network
NOTE: Upgraded AMP 200N with
firmware V3.00.00 and higher may
have also a built in R/L Network
NOTE: The R/L Network is no longer supported by the AMP 200N2.