AMETEK CTS    AMP 200N series 
Manual for Operation  V 4.0.3  8 / 60 
2  Standards covered by AMP 200N Series 
The AMP 200 is special designed for testing the following standards.  
 
ISO 11452-8 
SAE J1113-2 
Daimler Chrysler DC 10614-15 
Fiat 9.90110 Rev.13 (2007-03) 
GMW3097 
PSA/Renault EQ/IR 02 
VW TL 82566 
Mercedes MBN 10284-2 
Nissan 28401 NDS 02 Rev.4 
GLoyd GL VI-7-2 
 
 
 
external/internal Magnetic Fields 
Voltage Ripple Test, Closed loop / Substitution 
Daimler Chrysler DC10615 Rev D 
Fiat 9.90110 Rev.13 (2007-03) 
Immunity to Ground Voltage Offset 
Nissan 28401 NDS 02 Rev.4 
 
 
2.1  General 
The AMP 200N series have been designed as a low-frequency signal source to generate sinusoidal signals used 
to simulate ripple noise and ground shift noise as required by a variety of standards in the automotive industry 
e.g. as per Ford, CI 210 and CI 250 as well as RI 150. The AMP 200N is controlled by the EM TEST Autowave to 
also allow the generation of non-sinusoidal and customized signals. Additionally, the AMP 200N can be used to 
generate magnetic fields by means of a radiation loop or small Helmholtz coils as per RI 140 of Ford EMC-CS-
2009.1 and Ford FMC 1278.