AMETEK CTS AMP 200N series
Manual for Operation V 4.0.3 34 / 60
Standard setup as per Ford
For complete transient testing as
per Ford standard, the following
setup shows the wiring between
the different EM Test devices.
Rack 1 DC sources
RDS 200N control: AutoWave CH4 or PFS200
RDS 200N control: AutoWave CH3
AMP 200N
AutoWave
PFS 200N
VDS 200N
Rack 2 Pulses
LD 200N
UCS 200N
Figure 14 Setup 8
Remark: Control cable for RDS200
Ford CI 230 RDS200: analog in 0-10V to AutoWave CH4
PFS 200 application RDS200: analog in 0-10V to PFS200 0-10V
12.4.1 Setup for Magnetic Field Immunity: RI 140
Magnetic field immunity requirements cover the frequency range from 50 Hz to 100 kHz. Requirements are
based on anticipated “off-vehicle” electromagnetic sources (e.g. AC power lines) in addition to “on-vehicle”
sources (e.g. charging system, PWM sources)
Default test setup