M470039-01 REV-F  Page  153 
 
*Recommended tools: adjustable ranch x 2pcs 
Install INLET TOP interconnect pipe to female threaded pipe at PLW rear panel.  
Install INLET BOTTOM interconnect pipe to female threaded pipe at PLW rear panel. Using 
one ranch fixed position on the female threaded pipe at PLW rear panel, and the other ranch 
torque carefully at the interconnect pipe, Tighten the male end connection into the mating 
female end connection until hand-tight approximately 2 threads. Then tighten the male end 
connection until wrench-tight approximately 2 threads. 
 
When installing the inlet and outlet pipes, be careful not to over-torque the male pipe fittings 
into the Inlet/Outlet pipe terminals.  This additional force may crack the inlet and/or outlet 
female piping on the eLoad.  
   
  Locate the FLUID INLET distribution pipe. Install onto the interconnect pipes. 
Using one ranch fixed position on the interconnect pipes, and the other ranch torque carefully 
at the distribution pipe.