109ARR1575
555051
555052
1
MAINTENANCE MANUAL
Every 50 hours of operation
3.6.11. Inspection of brakes
The function of the brakes must be checked periodically.
The cable / connector Y9, which must be disconnected for
the brake test, is located at the front under the hood.
Put the machine into the work gear.
Disconnect connector Y9 (1) from the connector housing at
the magnet.
Perform the forwards and backwards driving functions us-
ing the infrared sensor.
If abrake is defective, the corresponding drum will rotate.
Note:
If abrake is defective, the machine is no longer safe for opera-
tion. Contact your authorized dealer and have the machine re-
paired professionally.