110 ARR1575
555104A
1
1
3.6. Individual Operations of Maintenance
3.6.12. Battery check
Stop the engine.
Clean the surface of batteries.
Check the condition of poles and terminals (1) and clean
them. Slightly wipe terminals with grease.
MAINTENANCE-FREE BATTERY
In case of amaintenance-free battery (the battery has no fre-
ely accessible plugs), only the no-load voltage on terminals
is checked. The batteries cannot be replenished. If the no-
-load voltage is 12.6 Vand more, the battery is fully charged.
If the no-load voltage is below 12.4 V, the battery should be
charged immediately. After the battery is charged, leave it
to stand for 2–3 hours and then measure the voltage again.
It is recommended to be mounted 24 hours after charging.
Note:
The no-load voltage is the voltage measured at the terminals of
the battery which was at rest for at least 12 hours – was neither
charged nor discharged.
Keep the batteries dry and clean.
DoNOT disconnect battery while the engine runs.
When handling with the battery, always follow battery
Manufacturers Manual!
Use rubber gloves and eye protection aids when han-
dling the battery.
Use proper clothing to protect your skin against any
electrolyte stain.
When there is eye contact with electrolyte immediately
ush aected eye with large amounts of water for afew
minutes. Get prompt medical attention.
When there is electrolyte ingestion, drink max amount
of milk, water, or solution of calcined magnesia in water.
During skin contact with electrolyte, remove clothing,
including shoes, ush aected points as soon as possi-
ble with soap water or solution of soda and water. Get
prompt medical attention.
DoNOT eat, drink or smoke while at work!
After work is completed, wash your hands and face thor-
oughly with water and soap!
DoNOT check awire is energized by touching Machine
frame.
Disconnect the battery before its repair, or when about
to handle the wires and electric devices within the wiring
circuit so to avoid ashort circuit.
When disconnecting the battery, please disconnect ca-
ble with (-) pole rst. When connecting, you must con-
nect (+) pole rst.
Making direct conductive connection between batterys
both poles you will cause ashort circuit with battery ex-
plosion hazard.
DoNOT turn over the batteries, electrolyte may pour out
from degassing batteries.
When there is electrolyte spillage, rinse the aected
place with water, and neutralize with lime.
Hand over old batteries that do not work for their
disposal.