2.6.2.2. Cable connection
Spiral cable connector
1 - Spiral cable connector / protective cover fastener
2 - Solar cells / Transmission elements
Automatic pairing function
If you wish to control the machine via the infrared remote control, you must rst perform a mutual assignment of addresses. This
is only necessary when registering a new infrared remote control to the machine.
Connect the cable to the transmitter.
Turn the ignition key to the „I“ position.
You can disconnect the cable after ca 3 seconds.
The cable is not needed for operation with infrared transmitter.
Display Cause
The green and red LEDs are blinking in unison quickly. The infrared remote control is paired with the control unit of the
machine.
Note:
This procedure normally only takes a maximum of about 3 seconds. If this blinking lasts longer or should even become permanent,
there is a problem with pairing:
A cable break in one of the signal lines
A short circuit in one of the signal lines