75ARR1575
OPERATION MANUAL
Starting of the engine
First attempt to start:
Turn the key in the ignition switch clockwise to the III position.
The starting attempt was successful, the engine is running: Refer
to section „The engine is running“.
The starting attempt was unsuccessful, the engine is not ru-
nning: There might be air in the fuel system. Refer to section
„Checking the pump“.
Checking the pump
Turn the ignition key clockwise to the I position.
Check if the electric fuel pump is working.
Let the pump run for about 1 minute. The system will automati-
cally vent any air.
Second attempt to start:
Turn the ignition key clockwise to the III position.
Keep the engine running at idle speed.
Do not activate any function.
The engine is running
Keep the engine running at idle speed.
The engine will exhaust smoke until the oil accumulated in the
exhaust system completely burns (this make take up to 1 hour).
Immediately visually check for any signs of uid leakage.
If no problems were detected, set the engine to maximum spe-
ed, check the functions.
Risk of re!
The exhaust pipe may shoot ames or glowing embers.
The amount of smoke coming out of the engine should gradua-
lly and noticeably decrease. If the amount of smoke coming out
of the engine does not gradually decrease, the engine may be
mechanically damaged.
Turn o the engine.
Check the levels of all uids, rell if necessary.
Check uid losses.
Start the engine.