Axpert-Eazy AC Variable Frequency Drive
6-115
6
No.
Name
Code
56 DISPLAY_FLG 062 X1 (0-7) Flag (n) 000 It will display value of selected Flag (n) on X1 bit
location.
57 LPF1 063 Register (n)
Register
(m)
Tc (0-100)
Inputs = Register (m) and Tc (in mS)
LPF Output = Register (n)
58 LPF2 064 Register (n)
Register
(m)
Tc (0-100)
59 LPF3 065 Register (n)
Register
(m)
Tc (0-100)
60 LPF4 066 Register (n)
Register
(m)
Tc (0-100)
61 JMPC 067 X (1-100) Flag (n) 000 If Flag (n) = 1, then JUMP to X Command no.
62 JMPNC 068 X (1-100) Flag (n) 000 If Flag (n)! = 1, then JUMP to X Command no.
• Range of n, n1, n2 and m are 0 to 114 for register and 0 to 99 for flag.
• Register 0 to 85 have Read and Write access. Register 86 to 114 are Read Only.
• Flag status is single bit locations, which is 0 to 99.
• Memory Locations for Registers and Flag status are different.
• X1 indicate Display parameter (M313 to M323)
• X indicates Command No.