Programming
45
Modero S Series Touch Panels - Configuration & Programming Manual
Page Commands
Panel Commands (Cont.)
WAKE Force the panel out of screen saver mode.
•Syntax:
"'WAKE'"
•Example:
SEND COMMAND Panel,"'WAKE'"
Forces the panel out of the screen saver mode.
Page Commands
@APG Add a specific popup page to a specified popup group if it does not already exist. If the new popup is added to a group which has
a popup displayed on the current page along with the new pop-up, the displayed popup will be hidden and the new popup will be
displayed.
•Syntax:
"'@APG-<popup page name>;<popup group name>'"
•Variables:
popup page name = 1 - 50 ASCII characters. Name of the popup page.
popup group name = 1 - 50 ASCII characters. Name of the popup group.
•Example:
SEND_COMMAND Panel,"'@APG-Popup1;Group1'"
Adds the popup page ’Popup1’ to the popup group ’Group1’.
@CPG Clear all popup pages from specified popup group.
•Syntax:
"'@CPG-<popup group name>'"
•Variables:
popup group name = 1 - 50 ASCII characters. Name of the popup group.
•Example:
SEND_COMMAND Panel,"'@CPG-Group1'"
Clears all popup pages from the popup group ’Group1’.
@DPG Delete a specific popup page from specified popup group if it exists.
•Syntax:
"'@DPG-<popup page name>;<popup group name>'"
•Variables:
popup page name = 1 - 50 ASCII characters. Name of the popup page.
popup group name = 1 - 50 ASCII characters. Name of the popup group.
•Example:
SEND_COMMAND Panel,"'@DPG-Popup1;Group1'"
Deletes the popup page ’Popup1’ from the popup group ’Group1’.
@PDR Set the popup location reset flag. If the flag is set, the popup will return to its default location on show instead of its last drag
location.
•Syntax:
"'@PDR-<popup page name>;<reset flag>'"
•Variables:
popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.
reset flag = 1 = Enable reset flag, 0 = Disable reset flag
•Example:
SEND_COMMAND Panel,"'@PDR-Popup1;1'"
Popup1 will return to its default location when turned On.
@PHE Set the hide effect for the specified popup page to the named hide effect.
•Syntax:
"'@PHE-<popup page name>;<hide effect name>'"
•Variables:
popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.
hide effect name = Refers to the popup effect names being used.
•Example:
SEND_COMMAND Panel,"'@PHE-Popup1;Slide to Left'"
Sets the Popup1 hide effect name to ’Slide to Left’.