val: 1 to 5
bytes: number of bytes in the bi nary_data string
bi nary_
data: fre quency and dB off set
Re marks: This com mand up dates the off set ta ble speci fied by <val>. <bytes> is
the number of bytes in the bi nary_data string and <bi nary_data> is a
string which rep re sents the fre quency and the dB off set to ap ply in the
for mat of: <ele ment1><ele ment2><ele mentn...>, where <ele mentn>
has four bytes to rep re sent the fre quency and four bytes to rep re sent the
dB value. The four byte value can be cre ated by mul ti ply ing the float ing
point number by 1024 and con vert ing the LONG number to an AS CII
string. For ex am ple: –10.234 be comes 10479, con verted to hexa deci mal
FFFFD711. See the pro gram ming ex am ples for more de tail.
OFFTYP Off set type to use
SEN SOR
Syn tax: OFFTYP <s>,<type>
s: A or B
type: OFF
FIXED
TA BLE
Re marks: Se lects the type of off set to use.
OFF = No off set to be used.
FIXED = Use the fixed value (OFFFIX) spec i fied.
TA BLE = Use the Off set ta ble (OFFTBL) spec i fied.
Query: OFFTYP? <s>
Re turned
String: OFFTYP <s>,<type>
OFFVAL Sensor Off set Val ue
SEN SOR
Syn tax: OFFVAL <s>
s: A or B
Re marks: Returns the Off set value be ing ap plied to the spec i fied sen sor.
Re lated
Com mands: OFFTBL, OFFTYP
OGBD Out put Graph Bi nary Data
DATA OUT PUT
Syn tax: OGBD
6-64 ML2400A OM
ML24XXA NATIVE COMMANDS GPIB OPERATION