Ap pen dix C
Menu Maps
C-1 INTRODUCTION The ML2400A Se ries Power Me ter is driven by five main menus; Sen sor, Chan -
nel, Trig ger, Sys tem, and Cal/Zero, each ac cessed by a key on the front panel.
This ap pen dix con tains menu list ings rep re sent ing the lev els of the avail able
menus. Each menu be gins on the left with the front panel key for that menu,
with each sub se quent softkey level in dented from there. Avail able choices,
ranges, or lim its are shown in ital ics where ap pro pri ate. GPIB com mands that
are re lated to the menu se lec tions are shown on the far left in brack ets. Re fer
to Chap ter 6, GPIB Op er a tion for in for ma tion on us ing GPIB.
Note that many menu choices are con di tional de pend ing upon the me ter’s op -
er a tion mode, so that some menu op tions may not al ways be avail able as
shown. Re fer to Chap ter Four, Op er a tion, for more de tailed ex pla na tions of
menu func tions.
C-2 SENSOR MENU The Sen sor menu pres ents con trols for sen sor data pro cess ing.
Sen sor
Setup
SEN SOR NOT in ML2407A
A | B
[SENSTL ] SET TLE% per read ing } avail able in read out and power vs. time sys tem
} setup modes with de fault mea sure ment mode
} and read out mode = stan dard
0.01 to 10%
[SENMM ] Mea sure ment MODE } avail able in read out and power vs. time
} sys tem setup modes and
} read out mode = stan dard
De fault | mod av er age | cus tom
[RGH ] Range HOLD } not avail able in power vs. time sys tem setup
} mode
Auto | 1 to 5
CalFactor
SEN SOR } not in ML2407A
A | B
[CFSRC, CFVAL ] SOURCE
ML2400A OM C-1