Re marks: Hold fil ter sets the fil ter mode to Man ual from Auto, but re tains the
auto fil ter set ting. This func tion is the same as the AVGM com mand.
Re lated
Com mands: FM, FH, FA
FM Set av er age value
Syn tax: FM<val>EN
val: 0 to 9
Re marks: Sets the fil ter length for the av er ag ing of sen sor data. For HP 438A
emu la tion, the fil ter length is de fined as the number 2 to the power of
<val>. For ex am ple, the com mand FM5EN would be 2
5
, or 32.
Re lated
Com mands: FH, FA
GT Set group trig ger
Syn tax: GT<mode>
mode: 0
1
2
Re marks: 0 = Ig nore Group Exe cute Trig ger (GET) com mand
1 = Trig ger im me di ate re sponse to ‘GET’ com mand
2 = Trig ger with de layed re sponse to ‘GET’ com mand
The GTn com mand con fig ures what the de vice does when it re ceives the
‘GET’ com mand.
For ex am ple: GT1 sets the’ GET’ (Group Exe cute Trig ger) to per form a
TR1 type trig ger.
Re lated
Com mands:
TR
KB Cali bra tion fac tor
Syn tax: KB<val><ter mi na tor>
val: 1.0 to 150.0%
ter mi na tor: %
PCT
EN
6-124 ML2400A OM
HP 438A EMULATION COMMANDS GPIB OPERATION