Step 4. Connect the receiver cable to the output of the power splitter.
Step 5. Adjust the power using the attenuator knobs until the receiver being tested drops
the signal.
Softkeys
The following soft keys are available in CW Signal Generator mode:
q
Freq — Enter a CW frequency from 25 MHz to 3000 MHz using the
Up/Down arrow key, or the keypad and the appropriate soft key for Hz, kHz,
MHz or GHz. Press ENTER to accept the input.
q
Display Setup Help — Selecting this soft key displays a diagram of the rec
-
ommended setup to use this option.
15-2