Power Meter Menus (Option 29)
Selecting Power Meter from the mode menu causes the soft keys, described below, to be
displayed and the corresponding values shown in the message area.
The following soft keys are available when the FREQ/DIST key is pressed.
q
Center Activates the center frequency function and sets the power meter to
the center frequency. A frequency from 4.5 MHz to 2.9985 MHz can be en
-
tered.
q
Span Opens the parameter for editing and activates a menu of span related
choices.
q
Edit Allows editing of the span to enter specific frequency.
q
Full Sets the power meter to its maximum frequency span.
q
Min Minimum span in Power Meter mode is 3 MHz.
q
Span Up 1-2-5 Activates the span function so that the span may be in
-
creased quickly in a 1-2-5 sequence.
q
Span Down 1-2-5 Activates the span function so that the span may be
reduced quickly in a 1-2-5 sequence.
q
Back Returns to the previous menu level.
q
Signal Standard ¾ Opens a menu of soft keys used to select the signal stan-
dard to be used.
q Select Standard ¾ Opens the signal standard menu, showing the cur-
rently selected signal standards. Use the soft keys to navigate the list.
Press the
Show All soft key to show the complete signal standard list.
When the complete list is displayed, the currently selected signal stan-
dards are marked with an asterisk. Press the
Show Selected soft key to
show only the currently selected signal standards.
q
Start Channel ¾ Sets the channel information for the available standard.
If the particular standard has not been used before, the channel number
will default to the lowest legal channel number for that standard. If that
standard has been used before, the last used channel will be the default.
q
Uplink ¾ Selects the bank of frequencies that correspond to signals sent
from the client transmitter to the base station.
q
Downlink ¾ Selects the bank of frequencies that correspond to the signals
sent from the base station to the client receivers.
q
Back ¾ Returns to the previous menu.
The following soft keys are available when the AMPLITUDE key is pressed.
q
Units Choose either Watts or dBm.
q
Rel Selects whether relative power is on or off. When on, the message
Relative: On will show in the message area.
q
Offset Turns offset on or off. When on, a value from 0-60 dB can be en
-
tered.
q
Zero Turns zero adjust on or off.