13
7.12 AOP: Automatic power on
1.Enter FUNC MENU, choose NO. 12 function menu.
2.Press [PUSH] key to enter function setting, the chosen menu value in LCD will turn to
green color.
3.Turn channel switch to choose wanted setting.
ON: Turn on Automatic power on.
OFF: Turn off Automatic power on.
4.Press [PUSH] key or key to conrm and exit..
7.13 SWR:Standing wave ratio test
7.14 RST: Resume factory default
1.Enter FUNC MENU, choose NO. 14 function menu.
2.Press [PUSH] key to enter function setting, the chosen menu value in LCD will turn to
green color.
3.Turn channel switch to choose wanted setting.
OPT: All function settings resume factory default.
ALL: All channel and function settings resume factory default.
4.Press [PUSH] key to conrm.
5.Press key to stop and exit resume default function,
»
Connect a 50 ohm load before testing SWR !
1.Enter FUNC MENU,choose NO.13 function menu.
2.Press [PUSH] key to enter function setting.
3.Turn channel switch to choose wanted setting.
Continue:enter into SWR testing.
No:exit.
4.Press [PUSH] key to conrm.