62
BASE KEYWORD DESCRIPTION VALUE
LIST :FILE:ADD <file_name> Add File
0-9, A – Z, Limit 23 characters
for filename.
:FILE:EDIT|OPEN <file_name>
:EDIT|OPEN?
Edit or Open File
FILE:LOAD <file_name>
:LOAD?
Copy File
:FILE:COPY <file_source>,<file_destination> Copy File
:FILE:DELete <file_name> Delete File
:FILE:TOTal? Query File Total
:FILE:INDex <value>
:FILE:INDex?
Set File Index
:FILE:NAME? Query File Name
LIST
:PROGram:COUNt
:PROGram:COUNt?
Count 0 – 50000, 0 = Continuous
:PROGram:TRIGger <value>
:PROGram:TRIGger?
Set Trigger Mode AUTO, MANual
:PROGram:BASE <value>
:PROGram:BASE?
Set Base Value TIME, CYCLe
:PROGram:RANGe <value>
:PROGram:RANGe?
Set Voltage Range AUTO, HIGH, LOW
:PROGram:VOLTage:AC <value>
:PROGram:VOLTage:AC?
Set Output AC Voltage 0.0 – 310.0 VAC
:PROGram:VOLTage:DC <value>
:PROGram:VOLTage:DC?
Set Output DC Voltage 0.0 – 420.0 VDC
:PROGram:FREQuency
:PROGram:FREQuency?
Set Frequency 5 – 1200 Hz
:PROGram:ANGLe:CONTinue <value>
:PROGram:ANGLe:CONTinue?
Set Angle Continue ON, OFF
:PROGram:FAILStop <value>
:PROGram:FAILStop?
Set Fail Stop ON, OFF
:SEQuence:ADD <value> Add Sequence
:SEQuence:EDIT|OPEN <value>
:SEQuence:EDIT|OPEN?
Edit or Open Sequence
B) Manual Mode Commands and Companion Queries
These commands are used to modify test parameters for the Manual mode on the instrument. The
operating mode of the unit should be put in Manual mode for the commands below to work successfully.
These commands require a parameter value to be included with the command. The companion query
command will read the parameter using the same value that is used for setting the parameter.