BASE KEYWORD DESCRIPTION VALUE
LIST :SEQuence:COPY <value> Copy Sequence
:SEQuence:DELete <value> Delete Sequence
:SEQuence:TOTal? Query Sequence Total
:SEQuence:WAVE
:SEQuence:WAVE?
Set Output Waveform
SINE, TRIangle, SQUare,
CLIPped
:SEQuence:THD <value>
:SEQuence:THD?
Set THD Value *Clipped wave only
:SEQuence:ANGLe[:STARt]
:SEQuence:ANGLe[:STARt]?
Set Start Angle 0 – 359°
:SEQuence:VOLTage:AC:STARt <value>
:SEQuence:VOLTage:AC:STARt?
Set Output Start AC Voltage 0.0 – 310.0 VAC
:SEQuence:VOLTage:AC:END <value>
:SEQuence:VOLTage:AC:END?
Set Output End AC Voltage 0.0 – 310.0 VAC
SEQuence:VOLTage:DC:STARt <value>
:SEQuence:VOLTage:DC:STARt?
Set Output Start DC Voltage 0.0 – 420.0 VDC
:SEQuence:VOLTage:DC:END <value>
:SEQuence:VOLTage:DC:END?
Set Output End DC Voltage 0.0 – 420.0 VAC
:SEQuence:FREQuency:STARt <value>
:SEQuence:FREQuency;STARt?
Set Output Start Frequency 5 – 1200 Hz
:SEQuence:FREQuency:END <value>
:SEQuence:FREQuency;END?
Set Output End Frequency 5 – 1200 Hz
:SEQuence:TIME[:DWELl] <value>
:SEQuence:TIME[:DWELl]?
Set Dwell Time 1.0 – 999.9
:SEQuence:TIME:UNIT <value>
:SEQuence:TIME:UNIT?
Set Time Unit HOUR, MINute, SECond, MS
:SEQuence:CURRent[:LIMit]:HIGH
:SEQuence:CURRent[:LIMit]:HIGH?
Set Current High Limit
0.05 – 12.50 A, 0 = OFF*
See Specs
:SEQuence:CURRent[:LIMit]:LOW
:SEQuence:CURRent[:LIMit]:LOW?
Set Current Low Limit
0.05 – 12.50 A, 0 = OFF*
See Specs
:SEQuence:POWer[:LIMit]:HIGH
:SEQuence:POWer[:LIMit]:HIGH?
Set Power High Limit
0 – 1250 W, 0 = OFF* See
Specs
:SEQuence:POWer[:LIMit]:LOW
:SEQuence:POWer[:LIMit]:LOW?
Set Power Low Limit
0 – 1250 W, 0 = OFF* See
Specs
:SEQuence:PFACtor[:LIMit]:HIGH
:SEQuence:PFACtor[:LIMit]:HIGH?
Set Power Factor High Limit 0.000 – 1.000, 0 = OFF
:SEQuence:PFACtor[:LIMit]:LOW
:SEQuence:PFACtor[:LIMit]:LOW?
Set Power Factor Low Limit 0.000 – 1.000, 0 = OFF
:SEQuence:APEAK[:LIMit]:HIGH
:SEQuence:APEAK[:LIMit]:HIGH?
Set Peak Amps High Limit
0.0 – 50.0 A, 0 = OFF* See
Specs
:SEQuence:APEAK[:LIMit]:LOW
:SEQuence:APEAK[:LIMit]:LOW?
Set Peak Amps Low Limit
0.0 – 50.0 A, 0 = OFF*
See Specs
:SEQuence:REACtive[:LIMit]:HIGH
:SEQuence:REACtive[:LIMit]:HIGH?
Set Reactive Power High Limit
0 – 1250 VAR, 0 = OFF*
See Specs
SEQuence:REACtive[:LIMit]:LOW
:SEQuence:REACtive[:LIMit]:LOW?
Set Reactive Power Low Limit
0 – 1250 VAR, 0 = OFF*
See Specs