© Ikonix USA
64
BASE KEYWORD DESCRIPTION VALUE
:SEQuence:CREStfactor[:LIMit]:HIGH
:SEQuence:CREStfactor[:LIMit]:HIGH?
Set Crest Factor High Limit 0.00 – 10.00, 0 = OFF
:SEQuence:CREStfactor[:LIMit]:LOW
:SEQuence:CREStfactor[:LIMit]:LOW?
Set Crest Factor Low Limit 0.00 – 10.00, 0 = OFF
:SEQuence:APParent[:LIMit]:HIGH
:SEQuence:APParent[:LIMit]:HIGH?
Set Apparent Power High
Limit
0 – 1250 VA, 0 = OFF*
See Specs
:SEQuence:APParent[:LIMit]:LOW
:SEQuence:APParent[:LIMit]:LOW?
Set Apparent Low Limit
0 – 1250 VA, 0 = OFF* See
Specs
BASE KEYWORD DESCRIPTION VALUE
STEP :FILE:ADD <file_name> Add File
0-9, A – Z, Limit 23 characters
for filename.
:FILE:EDIT|OPEN <file_name>
:EDIT|OPEN?
Edit or Open File
FILE:LOAD <file_name>
:LOAD?
Load a File
:FILE:COPY <file_source>,<file_destination> Copy File
:FILE:DELete <file_name> Delete File
:FILE:TOTal? Query File Total
:FILE:INDex <value>
:FILE:INDex?
Set File Index
:FILE:NAME? Query File Name
COUNt
:COUNt?
Count 0 – 50000, 0 = Continuous
:TRIGger <value>
:TRIGger?
Set Trigger Mode AUTO, MANual
:BASE <value>
:BASE?
Set Base Value TIME, CYCLe
:RANGe <value>
:RANGe?
Set Voltage Range AUTO, HIGH, LOW
:SEQuence:WAVE
:SEQuence:WAVE?
Set Output Waveform
SINE, TRIangle, SQUare,
CLIPped
SEQuence:THD <value>
:SEQuence:THD?
Set THD Value *Clipped wave only
C) Step Mode Commands and Companion Queries
These commands are used to modify test parameters for the Step mode on the instrument. The operating
mode of the unit should be put in Step mode for the commands below to work successfully. These
commands require a parameter value to be included with the command. The companion query command
will read the parameter using the same value that is used for setting the parameter.